Re: [ap-gto] Re: 400GTO keypad


Feb 13 5:31 PM

 


----------------------------

#11939 Feb 13 5:31 PM

My keypad is working okay now. For future reference, if my keypad

ever stops working out in the middle of nowhere, I assume that my

mount will still track okay. Will I still be able to autoguide my

ST10 with CCDsoft for CCD imaging? Will I still be able to

calibrate to TheSky for GoTo slewing without the keypad?



Thanks,

Ruben



www.stardoctor.org



----------------------------

#11943 Feb 14 8:11 AM

In a message dated 2/13/2005 7:32:21 PM Central Standard Time,

stardoctor5@... writes:



> My keypad is working okay now. For future reference, if my keypad

> ever stops working out in the middle of nowhere, I assume that my

> mount will still track okay. Will I still be able to autoguide my

> ST10 with CCDsoft for CCD imaging? Will I still be able to

> calibrate to TheSky for GoTo slewing without the keypad?



The keypad can be completely removed and the mount will still function

perfectly fine in all respects. All that the mount needs to start and function

properly is a startup command sequence, and this can be sent from The Sky, or Pulse

Guide or any other program that sends this sequence (you can even do it

manually with Hyperterminal).



Roland Christen





[Non-text portions of this message have been removed]